Temperature Range: −20 °C ~ 200 °C, depending on model

Product Types: Heating & cooling circulators, benchtop cooling units, low-temperature circulators and reaction baths.

Configurations: Multiple capacities, temperature variants and optional configurations.

Applications: Laboratory reactors, distillation, condensation, chemical synthesis, material research, and temperature-sensitive process equipment.

Laboratory Temperature Control Solutions

The ULPMAT refrigeration & heating circulators covers a range of laboratory and process temperature control requirements, from dedicated heating circulation to combined heating and cooling, low-temperature circulation, and constant-temperature reaction baths.

Each product type is designed for different equipment configurations and operating conditions. Selection depends on the required temperature range, heat load, circulation flow, reservoir capacity, and connected apparatus.

Product Categories

  • Refrigeration and Heating Circulators — GDXH Series: Combined heating and cooling circulation for reactors, jacketed vessels, and other equipment requiring controlled thermal cycling.
  • Benchtop Cooling Circulators — DL Series: Compact cooling units for laboratory instruments, small apparatus, distillation, condensation, and electronic testing.
  • Heating Circulators — JBXH / FBXH / FRXH Series: Circulating heating systems available in standard, sealed, and explosion-proof configurations, depending on the selected model.
  • Low-temperature Cooling Liquid Circulating Pumps — DWXH Series: Low-temperature circulating systems for supplying cooling media to external equipment and supporting temperature-sensitive processes.
  • Low-temperature Constant-temperature Reaction Baths — DHFY Series: Integrated heating, refrigeration, and magnetic stirring for constant-temperature reactions and low-temperature material processing.

GDXH Series Refrigeration and Heating Circulator

The GDXH series uses a circulating pump and a closed heat-transfer system to provide heating and cooling for external equipment. The heat-transfer medium passes through the heating unit and refrigeration heat exchanger to achieve the required circulation temperature.

The closed pipeline design and heat exchanger support efficient heat transfer while reducing the amount of heat-transfer fluid required. The system is suitable for fine chemical processes, pharmaceutical applications, and new-material synthesis involving reactors and jacketed vessels.

Key Features

  • Combined heating and refrigeration in one circulation system
  • Closed heat-transfer circuit with an expansion vessel
  • High-efficiency heat exchange and continuous temperature adjustment
  • Circulation pump designed for high-temperature operation
  • Safety functions including delay, leakage, overload, and over-temperature protection
  • Water-cooled refrigeration and explosion-proof configurations available as specified for the selected model

Technical Specifications — GDXH −20 °C Series

Parameter GDXH-5/-20+200 GDXH-10/-20+200 GDXH-20/-20+200 GDXH-30/-20+200 GDXH-50/-20+200 GDXH-100/-20+200
Adaptable Device Capacity 1–5 L 5–10 L 10–20 L 10–30 L 10–50 L 50–100 L
Temperature Range −20 ~160 °C (no-load Temperature) −20 ~180 °C (no-load Temperature)
Temperature Accuracy PID control, ±1 °C
Heating Power 2 kW 3 kW 4 kW 5 kW 6 kW 9 kW
Compressor Power 935 W 885 W 1230 W 2340 W 2555 W 4540 W
Condenser / Refrigerant Finned condenser / R22
Recirculation Flow 20 L/min (DN15pipe Diameter) 30 L/min (DN20pipe Diameter)
Maximum Head 6 M 12 M
External Circulation Inlet / Outlet DN15
Net Weight 120 kg 120 kg 126 kg 144 kg 164 kg 215 kg
Power Supply 220 V / 16 A  220 V / 50 Hz, single-phase 220 V Air Switch 380 V / 50 Hz (air switch:TN-S,≥25A) 380 V / 50 Hz (air switch:TN-S,≥40A)

Temperature Variants

The GDXH series includes multiple refrigeration temperature variants to accommodate different process requirements.

  • −30 °C Series: Operating range specified as −30 to 200 °C under no-load conditions.
  • −40 °C Series: Operating range specified as −40 to 200 °C under no-load conditions.
  • −60 °C Series: Operating range specified as −60 to 180 / 200 °C, depending on model.
  • −80 °C Series: Operating range specified as −80 to 180 / 200 °C, depending on model.
  • Deep-cooling Models: Special configurations are listed in the product brochure; confirm the exact model and usable temperature range before ordering.

Please contact us for the full specification table for the required temperature variant.

DL Series Benchtop Cooling Circulator

The DL series is a compact cooling solution for laboratory instruments and small-scale process equipment. Compressor refrigeration and heat exchange in the reservoir provide a continuous cooling source for applications such as distillation, condensation, chemical experiments, pharmaceutical research, and electronic testing.

Key Features

  • Compact benchtop design
  • Air-cooled condenser with finned heat exchanger
  • Digital temperature display and PID control with PT100 sensor
  • Stainless-steel coil evaporator
  • Brushless DC circulation pump
  • Continuous operation under the specified ambient conditions

Technical Specifications

Parameter DL-450 DL-700
Operating Temperature Range −20 °C ~RT −20 °C ~RT
Cooling Power at 20 °C 450 W 700 W
Cooling Power at 0 °C 270 W 520 W
Cooling Power at −20 °C 70 W 200 W
Temperature Accuracy ±0.1 °C ±0.1 °C
Temperature Control Smart PID; PT100 internal temperature sensor; LCD display, 0.1 °C resolution
Pump Type Brushless DC pump, submersible
Pump Input Power 30 W 48 W
Maximum Pump Flow Rate 10 L/min 20 L/min
Maximum Pump Head 9 m 11 m
Dimensions (W × D × H) 250 × 405 × 510 mm 250 × 405 × 510 mm
Ambient Temperature 5–32 °C
Relative Humidity 80%

JBXH / FBXH / FRXH Series Heating Circulator

The heating circulator series supplies controlled heat to external instruments and process equipment through a circulating heat-transfer medium. The system is designed to improve heat utilization and support efficient heating in fine chemical processing, biopharmaceutical applications, and new-material synthesis.

Key Features

  • Circulating heating for external process equipment
  • Closed-system options with an expansion vessel
  • High-temperature circulation pump options
  • Digital temperature control
  • Leakage and phase-sequence protection, depending on model
  • Standard, sealed, and explosion-proof configurations

Available Configurations

JBXH Series — Standard Type

Designed for general heating circulation requirements. The series includes open heating-pot configurations and multiple reservoir capacities.

FBXH Series — Sealed Type

Uses a sealed circulation arrangement with filling and expansion tanks. The sealed circuit is designed to reduce exposure of the heat-transfer medium to air and moisture.

FRXH Series — Explosion-proof Type

Designed for applications requiring an explosion-proof configuration. The brochure specifies Ex d IIB T4 for this series; confirm the applicable model, certification, and installation requirements before selection.

General Technical Specifications

Parameter JBXH — Standard FBXH — Sealed FRXH — Explosion-proof
Temperature Range RT+15 to 180 °C; selected models up to 200 °C RT+10 to 180 °C; selected models up to 200 °C RT+10 to 180 / 200 °C, depending on model
Reservoir / Tank Capacity 5L–200 L Filling / expansion tank volume 6–20 L Confirm by selected model
Heating Power 1.5–18 kW 2–12 kW 1.5–18 kW explosion-proof rated power
Temperature Control Digital control, ±0.5 °C PID digital control, ±1 °C Confirm by selected model
Circulation Flow 12 / 30 / 42 L/min, depending on model 12–42 L/min Confirm by selected model
Pump Head 6–22 M 6–22 M Confirm by selected model
Power Supply 220 V or 380 V, depending on model Confirm by selected model Three-phase, five-wire system as specified in the brochure

Full specifications for individual models, including reservoir capacity, heating power, circulation flow, and power supply, are available on request.

DWXH Series Low-temperature Cooling Liquid Circulating Pump

The DWXH series uses compressor refrigeration and heat exchange in a reservoir to supply low-temperature heat-transfer fluid to external equipment. Depending on the setup, the reservoir can also accommodate containers for low-temperature reactions or material storage.

The series is suitable for chemical reactions, distillation, extraction, scientific research, semiconductor testing, pharmaceutical processes, and other applications requiring a cooling source.

Key Features

  • Multiple reservoir capacities for different cooling requirements
  • Air-cooled condenser with finned heat exchanger
  • Coil evaporator installed in the liquid reservoir
  • Magnetic circulation pump
  • Low-temperature variants and selected closed-type configurations
  • Water-cooled refrigeration and explosion-proof options available for selected models

Technical Specifications — Regular Type, −20 °C

Parameter DWXH-5/20 DWXH-10/20 DWXH-20/20 DWXH-30/20 DWXH-50/20 DWXH-100/20
Reservoir Capacity 5 L 10 L 20 L 30 L 50 L 100 L
Temperature Range −20 °C to room temperature (no-load)
Heat Exchanger / Refrigerant Nickel-plated copper tubes; finned condenser; R22
Compressor Power 580 W 935 W 1195 W 1750 W 2580 W 4540 W
Rated Cooling Capacity 1688 W 2805 W 3580 W 5574 W 8150 W 14500 W
Rated Circulating Flow 30 L/min (DN15pipe Diameter) 35 L/min (DN15pipe Diameter) 30 L/min (DN20pipe Diameter)
Pump Head 4 M 5 M 12 M
Total Rated Power 780 W 1120 W 1400 W 2000 W 2830 W 4900 W
Power Supply 220V/10AOne three-hole socket 220V/16A One three-hole socket 380V/50HZ (air switch:TN-S,≥25A)

Temperature and Configuration Options

The DWXH series also includes −40 °C, −80 °C, and −120 °C variants, as well as selected closed-type and explosion-proof configurations.

The exact operating range, cooling capacity, reservoir size, and refrigeration configuration depend on the selected model. Contact us for the complete specification table.

DHFY Series Low-temperature Constant-temperature Reaction Bath

The DHFY series combines compressor refrigeration, electric heating, temperature control, and magnetic stirring in an integrated reaction bath. It is designed for constant-temperature reactions, low-temperature synthesis, material processing, and temperature-controlled laboratory work.

The bath can accommodate suitable reaction vessels and can also be used as a temperature-controlled reservoir or an external cooling source, depending on the configuration.

Key Features

  • Integrated refrigeration and electric heating
  • Digital temperature control
  • Adjustable magnetic stirring on applicable models
  • Reservoir capacities from 5 L to 100 L in the listed model range
  • Coil evaporator designed for heat exchange in the reservoir
  • Water-cooled refrigeration and explosion-proof configurations available for selected models

Technical Specifications — DHFY −20 °C Series

Parameter DHFY-5/20 DHFY-10/20 DHFY-20/20 DHFY-30/20 DHFY-50/20 DHFY-100/20
Reservoir Volume 5 L 10 L 20 L 30 L 50 L 100 L
Actual Applicable Temperature Range −20 to 99 °C
Temperature Control Precision ±0.5 °C
Magnetic Stirring Power 5W Power 25W /
Heating Power 1500 W 2000 W 3000 W 4000 W 5000 W 6000 W
Refrigerant R22
Maximum Flow Rate 20L/min (DN15pipe Diameter) 30L/min (DN20pipe Diameter)
Accessories Silicone hose + insulation (2*2 m); Stainless-Steel Riser φ16mm

Temperature Variants

The DHFY series also includes −30 °C, −40 °C, −80 °C, and −120 °C. The no-load cooling range and actual applicable temperature range should be confirmed separately for each model.

For applications requiring low-temperature reaction control, please specify the required working temperature, reaction vessel dimensions, stirring requirements, and process load when requesting a quotation.

Applications of Refrigeration & Heating Circulators

The ULPMAT refrigeration and heating series supports laboratory research and process temperature control across a range of industries.

Fine Chemistry

Temperature control for spherical reactors, jacketed vessels, and chemical synthesis systems.

Pharmaceuticals

Heating and cooling support for crystallization, distillation, extraction, and other temperature-sensitive processes.

Biopharmaceuticals

Controlled thermal conditions for laboratory workflows and selected bioprocess applications.

Semiconductors and Electronics

Low-temperature circulation for electronic testing and compatible process equipment.

New Materials Research

Temperature management for polymerization, material synthesis, and advanced-material development.

Petrochemical and Research Laboratories

Heating and cooling sources for laboratory experiments, pilot plants, and process development.

Configure a Temperature Control System for Your Process

Selecting the appropriate temperature control equipment requires more than matching the nominal temperature range. The connected equipment, process heat load, circulation requirements, and operating environment also influence the configuration.

Depending on the series and model, available options may include:

  • Different operating temperature ranges
  • Multiple reservoir capacities
  • Different heating and cooling capacities
  • Circulation flow and pump head options
  • Standard or sealed circulation systems
  • Water-cooled refrigeration
  • Selected explosion-proof configurations

Information to Provide When Requesting a Quote

To help identify a suitable model, please provide the following information:

  • Required operating temperature range
  • Type and capacity of the connected equipment
  • Required heating or cooling capacity, if known
  • Required circulation flow rate and pump head, if known
  • Power supply and installation conditions
  • Required configuration and quantity

Our team can help review the application requirements and confirm the relevant model specifications before ordering.

Frequently Asked Questions

Q1. What is the difference between a refrigeration and heating circulator and a cooling circulator?

A refrigeration and heating circulator provides both heating and cooling within one circulation system. A cooling circulator is primarily designed to supply a cooling source. The appropriate choice depends on the required temperature range and whether the process requires both heating and cooling.

Q2. Which temperature ranges are available?

The series includes different temperature configurations, with the brochure describing overall options from −120 °C to 200 °C. The actual operating range depends on the product series, model, and configuration. Please confirm the required temperature range when requesting a quotation.

Q3. How do I choose the reservoir capacity?

Reservoir capacity should be selected according to the connected equipment, heat-transfer medium requirements, process load, and circulation arrangement. The capacity of the external reactor or apparatus should not be used as the only selection criterion.

Q4. Can these systems be connected to an external reactor?

Selected models are designed to provide circulating heating or cooling for external equipment, including reactors and jacketed vessels. Confirm the required inlet and outlet connections, flow rate, pump head, and temperature range before selecting a model.

Q5. Are sealed and explosion-proof configurations available?

Sealed and explosion-proof configurations are available in selected product series. Availability, specifications, and applicable certifications depend on the model. Please provide your operating environment and relevant requirements for confirmation.

Q6. Can I request a customized temperature control system?

Yes. Selected models offer configuration options such as different temperature ranges, reservoir capacities, and water-cooled refrigeration. Contact us with your application details to confirm the available options.

TDS

Contact us to obtain relevant TDS

Contact Us

If you need any service, please contact us

FAQs

Click to view the contents of our FAQs

More Information

more products

CONTACT US

Thermal Spray

Our website has been completely upgraded