Temperature Range: −20 °C ~ 200 °C, depending on model
Product Types: Heating & cooling circulators, benchtop cooling units, low-temperature circulators and reaction baths.
Configurations: Multiple capacities, temperature variants and optional configurations.
Applications: Laboratory reactors, distillation, condensation, chemical synthesis, material research, and temperature-sensitive process equipment.
The ULPMAT refrigeration & heating circulators covers a range of laboratory and process temperature control requirements, from dedicated heating circulation to combined heating and cooling, low-temperature circulation, and constant-temperature reaction baths.
Each product type is designed for different equipment configurations and operating conditions. Selection depends on the required temperature range, heat load, circulation flow, reservoir capacity, and connected apparatus.
The GDXH series uses a circulating pump and a closed heat-transfer system to provide heating and cooling for external equipment. The heat-transfer medium passes through the heating unit and refrigeration heat exchanger to achieve the required circulation temperature.
The closed pipeline design and heat exchanger support efficient heat transfer while reducing the amount of heat-transfer fluid required. The system is suitable for fine chemical processes, pharmaceutical applications, and new-material synthesis involving reactors and jacketed vessels.
| Parameter | GDXH-5/-20+200 | GDXH-10/-20+200 | GDXH-20/-20+200 | GDXH-30/-20+200 | GDXH-50/-20+200 | GDXH-100/-20+200 |
| Adaptable Device Capacity | 1–5 L | 5–10 L | 10–20 L | 10–30 L | 10–50 L | 50–100 L |
| Temperature Range | −20 ~160 °C (no-load Temperature) | −20 ~180 °C (no-load Temperature) | ||||
| Temperature Accuracy | PID control, ±1 °C | |||||
| Heating Power | 2 kW | 3 kW | 4 kW | 5 kW | 6 kW | 9 kW |
| Compressor Power | 935 W | 885 W | 1230 W | 2340 W | 2555 W | 4540 W |
| Condenser / Refrigerant | Finned condenser / R22 | |||||
| Recirculation Flow | 20 L/min (DN15pipe Diameter) | 30 L/min (DN20pipe Diameter) | ||||
| Maximum Head | 6 M | 12 M | ||||
| External Circulation Inlet / Outlet | DN15 | |||||
| Net Weight | 120 kg | 120 kg | 126 kg | 144 kg | 164 kg | 215 kg |
| Power Supply | 220 V / 16 A | 220 V / 50 Hz, single-phase | 220 V Air Switch | 380 V / 50 Hz (air switch:TN-S,≥25A) | 380 V / 50 Hz (air switch:TN-S,≥40A) | |
The GDXH series includes multiple refrigeration temperature variants to accommodate different process requirements.
Please contact us for the full specification table for the required temperature variant.
The DL series is a compact cooling solution for laboratory instruments and small-scale process equipment. Compressor refrigeration and heat exchange in the reservoir provide a continuous cooling source for applications such as distillation, condensation, chemical experiments, pharmaceutical research, and electronic testing.
| Parameter | DL-450 | DL-700 |
|---|---|---|
| Operating Temperature Range | −20 °C ~RT | −20 °C ~RT |
| Cooling Power at 20 °C | 450 W | 700 W |
| Cooling Power at 0 °C | 270 W | 520 W |
| Cooling Power at −20 °C | 70 W | 200 W |
| Temperature Accuracy | ±0.1 °C | ±0.1 °C |
| Temperature Control | Smart PID; PT100 internal temperature sensor; LCD display, 0.1 °C resolution | |
| Pump Type | Brushless DC pump, submersible | |
| Pump Input Power | 30 W | 48 W |
| Maximum Pump Flow Rate | 10 L/min | 20 L/min |
| Maximum Pump Head | 9 m | 11 m |
| Dimensions (W × D × H) | 250 × 405 × 510 mm | 250 × 405 × 510 mm |
| Ambient Temperature | 5–32 °C | |
| Relative Humidity | 80% | |
The heating circulator series supplies controlled heat to external instruments and process equipment through a circulating heat-transfer medium. The system is designed to improve heat utilization and support efficient heating in fine chemical processing, biopharmaceutical applications, and new-material synthesis.
JBXH Series — Standard Type
Designed for general heating circulation requirements. The series includes open heating-pot configurations and multiple reservoir capacities.
FBXH Series — Sealed Type
Uses a sealed circulation arrangement with filling and expansion tanks. The sealed circuit is designed to reduce exposure of the heat-transfer medium to air and moisture.
FRXH Series — Explosion-proof Type
Designed for applications requiring an explosion-proof configuration. The brochure specifies Ex d IIB T4 for this series; confirm the applicable model, certification, and installation requirements before selection.
| Parameter | JBXH — Standard | FBXH — Sealed | FRXH — Explosion-proof |
|---|---|---|---|
| Temperature Range | RT+15 to 180 °C; selected models up to 200 °C | RT+10 to 180 °C; selected models up to 200 °C | RT+10 to 180 / 200 °C, depending on model |
| Reservoir / Tank Capacity | 5L–200 L | Filling / expansion tank volume 6–20 L | Confirm by selected model |
| Heating Power | 1.5–18 kW | 2–12 kW | 1.5–18 kW explosion-proof rated power |
| Temperature Control | Digital control, ±0.5 °C | PID digital control, ±1 °C | Confirm by selected model |
| Circulation Flow | 12 / 30 / 42 L/min, depending on model | 12–42 L/min | Confirm by selected model |
| Pump Head | 6–22 M | 6–22 M | Confirm by selected model |
| Power Supply | 220 V or 380 V, depending on model | Confirm by selected model | Three-phase, five-wire system as specified in the brochure |
Full specifications for individual models, including reservoir capacity, heating power, circulation flow, and power supply, are available on request.
The DWXH series uses compressor refrigeration and heat exchange in a reservoir to supply low-temperature heat-transfer fluid to external equipment. Depending on the setup, the reservoir can also accommodate containers for low-temperature reactions or material storage.
The series is suitable for chemical reactions, distillation, extraction, scientific research, semiconductor testing, pharmaceutical processes, and other applications requiring a cooling source.
| Parameter | DWXH-5/20 | DWXH-10/20 | DWXH-20/20 | DWXH-30/20 | DWXH-50/20 | DWXH-100/20 |
|---|---|---|---|---|---|---|
| Reservoir Capacity | 5 L | 10 L | 20 L | 30 L | 50 L | 100 L |
| Temperature Range | −20 °C to room temperature (no-load) | |||||
| Heat Exchanger / Refrigerant | Nickel-plated copper tubes; finned condenser; R22 | |||||
| Compressor Power | 580 W | 935 W | 1195 W | 1750 W | 2580 W | 4540 W |
| Rated Cooling Capacity | 1688 W | 2805 W | 3580 W | 5574 W | 8150 W | 14500 W |
| Rated Circulating Flow | 30 L/min (DN15pipe Diameter) | 35 L/min (DN15pipe Diameter) | 30 L/min (DN20pipe Diameter) | |||
| Pump Head | 4 M | 5 M | 12 M | |||
| Total Rated Power | 780 W | 1120 W | 1400 W | 2000 W | 2830 W | 4900 W |
| Power Supply | 220V/10AOne three-hole socket | 220V/16A One three-hole socket | 380V/50HZ (air switch:TN-S,≥25A) | |||
The DWXH series also includes −40 °C, −80 °C, and −120 °C variants, as well as selected closed-type and explosion-proof configurations.
The exact operating range, cooling capacity, reservoir size, and refrigeration configuration depend on the selected model. Contact us for the complete specification table.
The DHFY series combines compressor refrigeration, electric heating, temperature control, and magnetic stirring in an integrated reaction bath. It is designed for constant-temperature reactions, low-temperature synthesis, material processing, and temperature-controlled laboratory work.
The bath can accommodate suitable reaction vessels and can also be used as a temperature-controlled reservoir or an external cooling source, depending on the configuration.
| Parameter | DHFY-5/20 | DHFY-10/20 | DHFY-20/20 | DHFY-30/20 | DHFY-50/20 | DHFY-100/20 |
|---|---|---|---|---|---|---|
| Reservoir Volume | 5 L | 10 L | 20 L | 30 L | 50 L | 100 L |
| Actual Applicable Temperature Range | −20 to 99 °C | |||||
| Temperature Control Precision | ±0.5 °C | |||||
| Magnetic Stirring | Power 5W | Power 25W | / | |||
| Heating Power | 1500 W | 2000 W | 3000 W | 4000 W | 5000 W | 6000 W |
| Refrigerant | R22 | |||||
| Maximum Flow Rate | 20L/min (DN15pipe Diameter) | 30L/min (DN20pipe Diameter) | ||||
| Accessories | Silicone hose + insulation (2*2 m); Stainless-Steel Riser φ16mm | |||||
The DHFY series also includes −30 °C, −40 °C, −80 °C, and −120 °C. The no-load cooling range and actual applicable temperature range should be confirmed separately for each model.
For applications requiring low-temperature reaction control, please specify the required working temperature, reaction vessel dimensions, stirring requirements, and process load when requesting a quotation.
The ULPMAT refrigeration and heating series supports laboratory research and process temperature control across a range of industries.
Fine Chemistry
Temperature control for spherical reactors, jacketed vessels, and chemical synthesis systems.
Pharmaceuticals
Heating and cooling support for crystallization, distillation, extraction, and other temperature-sensitive processes.
Biopharmaceuticals
Controlled thermal conditions for laboratory workflows and selected bioprocess applications.
Semiconductors and Electronics
Low-temperature circulation for electronic testing and compatible process equipment.
New Materials Research
Temperature management for polymerization, material synthesis, and advanced-material development.
Petrochemical and Research Laboratories
Heating and cooling sources for laboratory experiments, pilot plants, and process development.
Selecting the appropriate temperature control equipment requires more than matching the nominal temperature range. The connected equipment, process heat load, circulation requirements, and operating environment also influence the configuration.
Depending on the series and model, available options may include:
To help identify a suitable model, please provide the following information:
Our team can help review the application requirements and confirm the relevant model specifications before ordering.
A refrigeration and heating circulator provides both heating and cooling within one circulation system. A cooling circulator is primarily designed to supply a cooling source. The appropriate choice depends on the required temperature range and whether the process requires both heating and cooling.
The series includes different temperature configurations, with the brochure describing overall options from −120 °C to 200 °C. The actual operating range depends on the product series, model, and configuration. Please confirm the required temperature range when requesting a quotation.
Reservoir capacity should be selected according to the connected equipment, heat-transfer medium requirements, process load, and circulation arrangement. The capacity of the external reactor or apparatus should not be used as the only selection criterion.
Selected models are designed to provide circulating heating or cooling for external equipment, including reactors and jacketed vessels. Confirm the required inlet and outlet connections, flow rate, pump head, and temperature range before selecting a model.
Sealed and explosion-proof configurations are available in selected product series. Availability, specifications, and applicable certifications depend on the model. Please provide your operating environment and relevant requirements for confirmation.
Yes. Selected models offer configuration options such as different temperature ranges, reservoir capacities, and water-cooled refrigeration. Contact us with your application details to confirm the available options.
Contact us to obtain relevant TDS
If you need any service, please contact us
Click to view the contents of our FAQs